Tall brick chimney on a blue colonial cottage behind a split-rail fence

Gas Fireplace Repair When It Will Not Light or Stay Lit

Clicking with no flame, a pilot that drops out after a minute, a remote that does nothing.

Does This Match Your Sign?

Cause Found First
Fault Photos Shown
Repairs Written Up
Based in Palos Verdes Estates
Cause Found First
Fault Photos Shown
Repairs Written Up
Based in Palos Verdes Estates

What the Visit Covers

We test with a meter and a manometer before replacing anything, so you pay for the failed part and not a guess. Typical repairs are thermocouples, thermopiles, pilot assemblies, igniters, remote receivers, wall switches and, less often, gas valves. Parts and labor are quoted before install. After the repair we run a full cycle, leak-test the fittings we touched and check the room for carbon monoxide.

Pilot light and ignition system repair
Thermocouple and thermopile replacement
Gas valve diagnosis and replacement
Direct-vent and ventless unit service
Remote control and wall switch repair
CO safety test after every repair

Match the symptom to the part

Gas fireplaces fail in a handful of predictable ways. The pilot lights while you hold the knob in, then goes out the moment you let go: that is almost always a thermocouple that no longer senses the flame, or a pilot flame too weak to heat it. The pilot stays lit but the main burner will not come on from the wall switch or remote: look at the thermopile, the switch wiring or the remote receiver and its batteries. You hear the igniter clicking but nothing lights: the pilot orifice may be blocked by dust or a spider web, or the gas supply may be off or low. The burner lights but the flame is small and the room does not warm: low gas pressure, a partly closed valve or blocked burner ports. The unit shuts off by itself after running for a while: on vented models a safety switch may be tripping because exhaust is not leaving properly, which needs attention before the unit is used again.

Salt air does these controls no favors. In homes near the water in Redondo Beach, Hermosa Beach and the bluffs of Palos Verdes Estates, we see corroded thermocouple tips, pitted contacts and rusted valve parts on units that would last longer inland. A unit that has sat unused for months is also a common call, because insects nest in the pilot tube over the summer.

How we repair it safely

We test before we replace. A meter tells us whether a thermocouple or thermopile is producing enough voltage, and a manometer tells us whether gas pressure at the valve is where the manufacturer wants it. That way you pay for the part that failed, not three parts that might have. Common repairs are a new thermocouple or thermopile, a cleaned or replaced pilot assembly, a new igniter, a replaced remote receiver or wall switch, and, less often, a new gas valve. We use parts made for your model where they are available. Parts and labor are quoted before we install anything.

After any repair we light the unit, run it through a full cycle, check the fittings we worked on for leaks and test for carbon monoxide in the room. If a unit has a cracked firebox, a damaged vent or a problem that makes it unsafe, we shut it off, tag it and explain why. If the unit is old enough that parts are no longer made, we will tell you that plainly and show you what a replacement insert would involve, so you can compare the cost of a repair against the cost of replacing the unit.

  • Written Estimates
  • Same-Day Service
  • Upfront Pricing
  • Satisfaction Guaranteed
Call (626) 231-0489